OEM vfd 5 Hp 460v 220v Single Phase manufacturer
●Has advanced open-loop vector control performance and good voltage and current control technology;
●Starting torque: 0.5Hz/150% torque;
●Wide voltage range design, the wide voltage range reaches AC 3PH: 360V~450V;
●Inverters below 18.5kW (inclusive) have built-in braking units;
●Has the function of not shutting down in case of instantaneous power failure;
●Independent air duct design supports wall-mounted and floor-standing installation methods, providing customers with a more reliable and economical installation and use method.
Project |
Technical Parameters |
||
Enter |
Rated voltage |
3PH AC 380V |
|
Frequency |
50Hz/60Hz |
||
Voltage allowable variation range |
3PH AC 360V~450V |
||
Output |
Voltage |
0~440V |
|
Frequency |
Low frequency mode:0~300Hz High frequency mode:0~3000Hz |
||
Overload capacity |
G type machine: 110% long term; 150% 1 minute; 180% 1 second P type machine: 105% long term; 120% 1 minute; 150% 1 second |
||
Control characteristics |
Control method |
0: Ordinary V/F control; 1: Advanced V/F control: 2: Open-loop current vector control; 3: Separate V/F control |
|
Modulation |
Space voltage vector PWM modulation |
||
Starting torque |
150% rated torque at 0.5Hz (vector type V/F control) |
||
Frequency accuracy |
Digital setting: maximum frequency´+0.01%; analog setting: maximum frequency´±0.2% |
||
Frequency resolution |
Digital setting: 0.01Hz;Analog setting: Maximum frequency´0.05% |
||
Torque boost |
Automatic torque boost, manual torque boost 0.1% to 30.0% |
||
V/F curve |
0: Linear curve 1: Decreasing torque curve 1 (1.3 power) 2: Torque reduction curve 2 (1.5 power) 3: Torque reduction curve 3 (1.7 power) 4: Square curve 5: User-set V/F curve |
||
Acceleration and deceleration curve |
Three methods: linear acceleration and deceleration, S-curve acceleration and deceleration, and shortest acceleration and deceleration; Four acceleration and deceleration times, time unit (minute/second) optional |
||
DC braking |
Stop DC braking starting frequency: 0.00Hz~maximum output frequency; Braking time: 0.0~50.0s; Braking current: 0.0%~150.0% rated current |
||
Automatic voltage regulation (AVR) |
When the grid voltage changes, it can automatically keep the output voltage constant |
||
Automatic current limit |
Automatically limit the current during operation to prevent frequent overcurrent fault tripping |
||
Automatic carrier adjustment |
Automatically adjust carrier frequency according to load characteristics and temperature characteristics |
||
Run function |
Run command channel |
The operation panel, control terminal and serial port can be switched in a variety of ways. |
|
Frequency given channel |
Digital given, analog voltage given, analog current given, pulse given, serial port given, terminal given, multi-speed given, can be switched in a variety of ways |
||
Auxiliary frequency given |
Realize flexible auxiliary frequency fine-tuning and frequency combination calculations |
||
Pulse output terminal |
0~50kHz pulse square wave signal output, which can realize the output of physical quantities such as set frequency and output frequency. |
||
Analog output terminal |
2 analog signal outputs, each optional 0/4~20mA or 0/2~10V, can realize the output of physical quantities such as set frequency and output frequency. |
||
Operation panel |
LED display |
Can display 61 parameters such as set frequency, output frequency, output voltage, output current, etc. |
|
Button function selection |
Define the scope of some keys to prevent misoperation |
||
Protective function |
Phase loss protection (optional), overcurrent protection, overvoltage protection, undervoltage protection, overheating protection, overload protection, load loss protection, etc. |
||
Environment |
Place of use |
Indoor, no direct sunlight, no corrosion, no flammable gas, no oil mist, dust, etc. |
|
Ambient temperature |
-10℃~+40℃(The ambient temperature is between 40℃ and 50℃, please derate it for use.) |
||
Ambient humidity |
5%~95%RH,No water droplets condensation |
||
Altitude |
Derate for use above 1000 meters, and derate by 10% for every 1000 meters. |
||
Structure |
Protection level |
IP20 |
|
Cooling method |
Air-cooled, with fan control |
||
Installation method |
Wall-mounted, cabinet type |