    ZYV630B VFD are single-phase 220 VAC and three-phase 380 VAC mini inverters launched based on the market demand for low power, small size and low cost. Guide rail installation greatly improves installation efficiency.

    • Power range 1.5kW~11kW
    • Voltage level AC 1PH 220V
    • AC 3PH 380V

    ZYV630B-1R5G-T

    ●Has advanced open-loop vector control performance and good voltage and current control technology;

    ●Starting torque: 0.5Hz/150% torque;

    ●Wide voltage range design, the wide voltage range reaches AC 3PH: 320V~450V;

    ●Has the function of not shutting down in case of instantaneous power failure;

    ●It has functions such as motor speed tracking technology, PID control, high and low frequency operating mode switching, and intelligent rapid acceleration and deceleration adjustment.

    Project

    Technical Parameters

    Enter


    Rated voltage,frequency

    3PH AC380V;50Hz/60Hz

    1PH  AC220V;50Hz/60Hz

    Voltage allowable variation range

    3PHAC360V~450V

    1PHAC190V~250V

    Output


    Voltage

    0~440V

    0~220V

    Frequency

    0~999.9Hz

    Overload capacity

    110% long term 150% 1 minute 180% 5 seconds

    Control method

    V/F control, advanced vector control, simple vector control, torque control

    Control characteristics

    Frequency setting resolution


    Analog input

    0.1% of maximum output frequency

    Digital settings

    0.01Hz

    Frequency accuracy


    Analog input

    Within 0.2% of the maximum output frequency

    Digital input

    Within 0.01% of the set output frequency

    V/F control


    V/F curve (voltage frequency characteristics)

    The base frequency can be set arbitrarily from 0.5 to 3000Hz, and the multi-point V/F curve can be set arbitrarily. Various fixed curves such as constant torque, reduced torque 1, reduced torque 2, and square torque can also be selected.

    Torque boost

    Manual setting: 0.0~30.0% of rated output

    Automatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters

    Automatic current limiting and pressure limiting

    Whether during acceleration, deceleration or stable operation, it can automatically detect the motor stator current and voltage, and suppress it within the allowable range based on a unique algorithm to minimize the possibility of system fault tripping.

    Inductive vector control


    Voltage frequency characteristics

    Automatically adjust the output voltage-to-frequency ratio based on motor parameters and unique algorithm

    Torque characteristics

    Starting torque:

    100% rated torque at 5.0Hz (VF control)

    150% rated torque at 1.5Hz (simple vector control)

    150% rated torque at 0.5Hz (advanced vector control)

    Operating speed steady-state accuracy: ≤±0.2% rated synchronous speed

    Current and voltage suppression

    Full current closed-loop control, completely avoiding current impact, with complete overcurrent and overvoltage suppression functions

    Undervoltage suppression during operation

    Especially for users with low grid voltage and frequent fluctuations in grid voltage, even if the voltage is lower than the allowed voltage range, the system can maintain the longest possible operating time based on a unique algorithm and residual energy allocation strategy.

    Typical functions


    Multi-speed operation

    7-segment programmable multi-segment speed control, multiple operating modes available

    PID control

    RS485 communication

    Built-in PID controller (frequency can be preset);

    Standard configuration RS485 communication function, multiple communication protocols optional, with linkage synchronous control function

    Frequency setting


    Analog input

    DC voltage 0~10V, DC current 0~20mA (upper and lower limits optional)

    Digital input

    Operation panel setting, RS485 interface setting, UP/DW terminal control, and various combination settings with analog input

    Output signal


    Digital output

    1 Y terminal open collector output and 1 programmable relay output (TA, TC), up to 17 meaning options

    Analog output

    1 analog signal output, the output range can be flexibly set between 0~20mA or 0~10V, which can realize the output of physical quantities such as set frequency and output frequency.

    Automatic voltage stabilization operation

    You can choose dynamic voltage stabilization, static voltage stabilization, or unstabilized voltage according to your needs to obtain the most stable operating effect.

    Acceleration and deceleration time setting

    0.1s~999.9min continuously configurable

    Brake


    Energy consumption braking

    Energy consumption braking starting voltage, hysteresis voltage and energy consumption braking rate are continuously adjustable

    DC braking

    Stop DC braking starting frequency: 0.00~[F00.05] upper limit frequency

    Braking time: 0.0~30.0s; Braking current: 0.0%~50.0% of motor rated current

    Low noise operation

    The carrier frequency is continuously adjustable from 2.0KHz to 20.0KHz to minimize motor noise.

    Speed tracking restart function

    It can realize smooth restart and instantaneous stop restart function of the running motor.

    Counter

    An internal counter to facilitate system integration

    Run function

    Upper and lower limit frequency settings, frequency jump operation, reverse operation limit, slip frequency compensation, RS485 communication, frequency increase and decrease control, fault self-recovery operation, etc.

    Operation panel


    Show

    Double-row LED display, display status can be freely defined according to needs

    Operating status

    Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback amount, analog input and output, etc.

    Alarm content

    It can record two fault records, operating frequency, operating current, DC bus voltage and other operating parameter records when the fault trips.

    Protective function

    Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc.

    Environment


    Place of use

    Indoor, no direct sunlight, no corrosion, no flammable gas, no oil mist, dust, etc.

    Ambient temperature

    -10℃~+40℃(The ambient temperature is between 40℃ and 50℃, please derate it for use.)

    Ambient humidity

    5%~95%RH,No water droplets condensation

    Altitude

    Derate for use above 1000 meters, and derate by 10% for every 1000 meters.

    Structure


    Protection level

    IP20

    Cooling method

    Air-cooled, with fan control

    Installation method

    Wall-mounted