    ZYV610 frequency inverter are single-phase 220 VAC and three-phase 380 VAC compact inverters launched to meet market demand. It adopts V/F control method and speed sensorless vector control method (SVC), and has significant advantages such as high power density, high EMC specification design, and high protection performance.

    • Power range 0.75kW~2.2kW
    • Voltage level AC 1PH 220V
    • AC 3PH 380V

    ZYV610-1R5G-49vo

    Has advanced open-loop vector control performance and good voltage and current control technology;

    ●Starting torque: 0.5Hz/150% torque;

    ●Wide voltage range design, the wide voltage range reaches AC 3PH: 320V~450V;

    ●Has the function of not shutting down in case of instantaneous power failure;

    ●It has functions such as motor speed tracking technology, PID control, high and low frequency operating mode switching, and intelligent rapid acceleration and deceleration adjustment.

    Project

    Technical Parameters

    Enter

    Rated voltage,

    frequency

    3PH  AC380V,50Hz/60Hz

    1PH  AC220V,50Hz/60Hz

    Voltage allowable variation range

    3PH AC320V~450V

    1PH AC190V~250V

    Output

    Voltage

    0~440V

    0~220V

    Frequency

    Low frequency mode:0~300Hz  High frequency mode:0~3000Hz

    Overload capacity

    110% long term 150% 1 minute 200% 4 seconds

    Control method

    V/F control, advanced V/F control, V/F separation control, PG-free current vector control

    Control characteristics

    Frequency setting

    resolution

    Analog input

    0.1% of maximum output frequency

    Digital settings

    0.01Hz

    Frequency accuracy

    Analog input

    Within 0.2% of the maximum output frequency

    Digital input

    Within 0.01% of the set output frequency

    V/F control

    V/F curve (voltage frequency characteristics)

    The base frequency can be set arbitrarily at 0.5~300Hz, the multi-point V/F curve can be set arbitrarily, and various fixed curves such as constant torque, reduced torque 1, reduced torque 2, and square torque can also be selected.

    Torque boost

    Manual setting: 0.0~30.0% of rated output

    Automatic lifting: automatically determine the lifting torque according to the output current and combined with the motor parameters

    Automatic current limiting and pressure limiting

    Whether during acceleration, deceleration or stable operation, it can automatically detect the motor stator current and voltage, and suppress it within the allowable range based on a unique algorithm to minimize the possibility of system fault tripping.

    Inductive vector control

    Voltage frequency characteristics

    Automatically adjust the output voltage-to-frequency ratio based on motor parameters and unique algorithm

    Torque characteristics

    Starting torque:

    150% rated torque at 3.0Hz (VF control)

    150% rated torque at 1.0Hz (advanced VF control)

    150% rated torque at 0.5Hz (no PG current vector control)

    Operating speed steady-state accuracy: ≤±0.2% rated synchronous speed

    Speed fluctuation: ≤±0.5% rated synchronous speed

    Torque response: ≤20ms (without PG current vector control)

    Self-determination of motor parameters

    Without any restrictions, automatic parameter detection can be completed under both static and dynamic conditions of the motor to obtain the best control effect.

    Current and voltage suppression

    Full current closed-loop control, completely avoiding current impact, with complete overcurrent and overvoltage suppression functions

    Undervoltage suppression during operation

    Especially for users with low grid voltage and frequent fluctuations in grid voltage, even if the voltage is lower than the allowed voltage range, the system can maintain the longest possible operating time based on a unique algorithm and residual energy allocation strategy.

    Typical functions

    Multi-speed and swing frequency operation

    16-segment programmable multi-segment speed control, multiple operating modes available.

    Swing frequency operation: preset frequency and center frequency are adjustable, state memory and recovery after power outage

    PID control

    RS485 communication

    Built-in PID controller (frequency can be preset).

    Standard configuration RS485 communication function, with linkage synchronous control function

    Frequency setting

    Analog input

    DC voltage 0~10V, DC current 0~20mA (upper and lower limits optional)

    Digital input

    Operation panel setting, RS485 interface setting, UP/DW terminal control, and various combination settings with analog input

    Output signal

    Digital output

    2 Y terminal open collector outputs and 2 programmable relay outputs (TA, TB, TC), up to 61 meaning options

    Analog output

    2 analog signal outputs, the output range can be flexibly set between 0~20mA or 0~10V, which can realize the output of physical quantities such as set frequency and output frequency.

    Acceleration and deceleration time setting

    0.1s~3600.0min can be set continuously, S-shaped and linear modes are optional

    Low noise operation

    Carrier frequency is continuously adjustable from 1.0KHz to 16.0KHz

    Protective function

    Overcurrent, overvoltage, undervoltage, module failure, electronic thermal relay, overheating, short circuit, input and output phase loss, abnormal motor parameter tuning, internal memory failure, etc.

    Environment

    Place of use

    Indoor, no direct sunlight, no corrosion, no flammable gas, no oil mist, dust, etc.

    Ambient temperature

    -10℃~+40℃(The ambient temperature is between 40℃ and 50℃, please derate it for use.)

    Ambient humidity

    5%~95%RH,No water droplets condensation

    Altitude

    Derate for use above 1000 meters, and derate by 10% for every 1000 meters.

    Structure

    Protection level

    IP20

    Cooling method

    Air-cooled, with fan control

    Installation method