Leave Your Message
  • Phone
  • E-mail
  • Whatsapp
  • Whatsapp
    sreg
  • High quality low voltage soft starter 22kw supplier

    ZYR6 series intelligent motor soft starter is a new type of motor starting and protection device produced using power electronics technology, microprocessor technology and modern control theory technology. It can start and stop the motor smoothly and avoid direct starting and star/delta starting. , auto-coupling step-down starting and other traditional starting methods to start the motor caused by mechanical and electrical shock and other problems, and can effectively reduce the starting current and power distribution capacity, avoiding investment in capacity expansion. ZYR6 soft starter has a built-in current transformer. Users do not need external transformers and motor protectors when arranging cabinets. When using the product, an external bypass contactor and circuit breaker are required. The product is simple to operate, has reliable performance and has good starting effect.


    • Power range 5.5kW~630kW
    • Voltage level AC 3PH 220V~1140V

    ZYR6-132 3gdp

    ●Wide-screen LCD display facilitates user operation;

    ●Optimize the overload startup effect;

    ●Complete protection functions;

    ●Stable and reliable performance;

    ●Strong anti-interference;

    ●Micro power consumption;

    ●Product structure advantages:

    ①The primary terminal is led out, which facilitates installation and reduces faults;

    ②The secondary terminal is removable to facilitate wiring and after-sales service;

    ③The keyboard is removable.

    Project

    Technical Parameters

    Load type

    3-phase AC asynchronous motor

    Voltage

    AC 220V、380V、440V、660V、1140V-15%~+10%

    Rated current

    11-1200A

    Frequency

    50Hz/60Hz

    Soft start time

    2~60S(adjustable)

    Soft stop time

    2~60S(adjustable)

    Current limiting multiple

    1.5~5.0 Ie

    Initial voltage

    30%~70%Ue

    Protection level

    IP20

    Cooling method

    Natural air cooling

    Communication method

    RS485 serial communication

    Number of starts

    ≤10 times/hour

    Environmental conditions

    If the altitude exceeds 2,000 meters, the capacity should be reduced accordingly;

    The ambient temperature is between -25~+45℃;

    The corresponding humidity does not exceed 95% (20℃±5℃)

    No flammable, explosive, corrosive gases, or conductive dust;

    Installed indoors with good ventilation and vibration less than 0.5G.